Specific Heat and Heat of Fusion of Lithium Perchlorate
The specific heat of lithium perchlorate has been measured in an adiabatic calorimeter at 298-600 K with a sample containing 99.8percent of the main component; the melting point (Tf = 520.7 K) and the heat of fusion (ΔHf = 20040 +/- 100 J mole-1) have also been determined.It is shown that 0.2-0.4percent of water is incorporated in the lithium perchlorate structure.
Shmidt, N. E.,Golushina, L. N.,Sharpataya, G. A.,Lemeneva, D. G.