were diluted in MHB in order to reach OD~ 0.6 at the wavelength of 600
nm, then they were incubated at 37° C by shaking at 300 rpm. After 30
minutes of treatment, 500 L samples were collected, centrifuged at 3.500
rpm, and the medium was removed and replaced with 1 mM PI in PBS.
The samples were incubated in the dark at room temperature for 15 min
and then centrifuged at 3.500 rpm. The supernatant was removed and
replaced with 1X PBS. Bacterial cells were visualized using an OLYMPUS
BX 41 microscope; the images were taken with CSV1.14 software using a
CAMXC-30 for image acquisition. Fluorescent signal intensity was
assessed using a fluorescent plate reader (ex. 530 nm; em.620 nm).
[3]
For some reviews and papers, see: a) M. R. E. Santos, A. C. Fonseca,
P. V. Mendonica, R. Branco, A. C. Serra, P. V. Morais, J. F. J. Coelho,
Materials 2016, 9, 599; b) Y. Xue, H. Xiao, Y. Zhang, Int. J. Mol. Sci.
2015, 16, 3626-3655; c) F. Siedenbiedel, J. C. Tiller, Polymers 2012, 4,
46-71; d) M. B. Yagci, S. Bolca, J. P. A. Heuts, W. Ming, G. de With,
Progr. Org. Coat. 2011, 72, 343-347; e) C. Yao, X.-s. Li, Chin. J. Polym.
Sci. 2010, 28, 581-588; f) C. Yao, X. Li, K. G. Neoh, Z. Shi, E. T. Kang,
J. Membr. Sci. 2008, 320, 259-267; f) A. Muñoz-Bonilla, M. Fernández-
García, Polymeric Materials with Antimicrobial .Activity: From Synthesis
to Applications, Introduction to Antimicrobial Polymeric Materials. RSC
Publishing, London, UK, 2014; g) A. Muñoz-Bonilla, M. Fernández-
García, Prog. Polymer Sci. 2012, 37, 281-339; h) B. Ayfer, B. Dizman, M.
O. Elasri, L. J. Mathias, D. Avci, Des. Monomers Polym. 2005, 8, 437-
Statistical analysis
4
51; i) D. Joynes, D. C. Sherrington, Polymer 1996, 37, 1453-1462.
Data is represented as the mean ± standard deviation (S.D.), taken over ≥
[
4]
a) A. Figoli, J. Hoinkis, B. Gabriele, G. De Luca, F. Galiano, S. A. Deowan,
Int. Pat. Appl. WO2015/044335A2 (02.04.2015); b) F. Galiano, A. Figoli,
S. A. Deowan, D. Johnson, S. A. Altinkaya, L. Veltri, G. De Luca, R.
Mancuso, N. Hilal, B. Gabriele, J. Hoinkis, J. Membr. Sci. 2015, 482, 103-
3
independent experiments, with ≥ 3 technical replicates per experiment,
unless otherwise stated. Statistical significance was measured using the
analysis of variance (ANOVA) test or student t-test. p ≤ 0.05 was
considered significant and all statistical tests were two sided.
1
14; c) S. A. Deowan, F. Galiano, J. Hoinkis, D. Johnson, S. A. Altinkaya,
G. Gabriele, N. Hilal, E. Drioli, A. Figoli, J. Membr. Sci. 2016, 510, 524-
32.
A. W. Bauer, W. M. M. Kirby, J. C. Sherris, M. Turck, Am. J. Clin. Pathol.
966, 45, 493–496.
5
Acknowledgements
[5]
1
[
6]
7]
J. R. Morones-Ramirez, J. A. Winkler, C. S. Spina, and J. J. Collins, Sci.
Transl. Med. 2013, 5, 190ra81.
The work performed has received funding from the European
Union’s Horizon 2020 research and innovation programme under
grant agreement No 689427 for the project VicInAqua.
[
O. I. Parisi, M. Fiorillo, A. Caruso, A. R. Cappello, C. Saturnino, F. Puoci,
A. Panno, V. Dolce, H. El-Kashef, M. S. Sinicropi, Int. J. Pharm. 2014,
461, 163–170.
Thanks are also due to Dr. Antonio Palumbo Piccionello
[8]
a) H. J. Benson, Microbiological Applications: Laboratory Manual in
General Microbiology, 7th ed. McGraw-Hill, Boston, Massachusetts,
(
University of Palermo, Italy) for MS measurements.
1
998, pp 139–141; b) H. J. Benson, Microbiological Applications:
Laboratory Manual in General Microbiology, 8th edn., McGraw-Hill,
Boston, Massachusetts, 2002, 432; c) Clinical and Laboratory
Keywords: antimicrobial polymers • antifouling membranes •
organic synthesis • polymerizable quaternary ammonium salts •
quaternary ammonium salts
p
Standards Institute; Approved Guideline, 2004, document M44-A;
Wayne, PA, USA.
[9]
a) Clinical and Laboratory Standards Institute; Approved Guideline, 2012
document M02-A11; Wayne, PA, USA; b) Clinical and Laboratory
Standards Institute; Approved Guideline, 2013, document M100-S23;
Wayne, PA, USA; c) Clinical and Laboratory Standards Institute.
Approved Guideline, 2008, document M27-A3; Wayne, PA, USA.
[
1]
2]
For reviews, see: a) G. McDonnel, D. Russell, Clin. Microbiol. Rev. 1999,
2, 147-179; b) M. Tischer, G. Pradel, K. Ohlsen, U. Holzgrabe,
1
ChemMedChem 2012, 7, 22-31.
[
For reviews, see: a) Shahid-ul-Islam, B. S. Butola, F. Mohammad, RSC
Adv. 2016, 6, 44232-44247; b) S. Bhowmick, S. Mohanty, V. Koul, J
Mater Sci: Mater Med, 2016, 27, 160; c) D. S. Morai, R. M. Guedes, M.
Ascensão Lopes, Materials 2016, 9, 498; d) L. Windler, M. Height, B.
Nowack, Environ. Int. 2013, 53, 62-73; e9 B. Simonic, B. Tomsic, Text.
Res. J. 2010, 80, 1721-1737; f) Y. Gao, R. Cranston, Text. Res. J. 2008,
[
10] a) Clinical and Laboratory Standards Institute; Approved Guideline, 2012,
document M07-A9; Wayne, PA, USA; b) M. Balouiri, M. Sadiki, S. K.
Ibnsouda, J. Pharm. Anal. 2016, 6, 71-79.
78, 60-72.