Revision Date: 08-16-2007
Material Safety Data Sheet
.
1. Chemical Product and Company Identification
space
Material Name PCB Congener mix for Method 525.2
space
01
Version #
space
Mixture
CAS #
space
N9331039
Item #
space
Acetone solution containing trace elements
Synonym(s)
space
PerkinElmer Life and Analytical Sciences
Identification Of The
710 Bridgeport Avenue
Company/Undertaking
Shelton, CT 06484
space
Technical Support 800-762-4000
space
CHEMTREC 800-424-9300
Emergency Telephone
Emergency Phone 800-762-4000
Number
.
2. Composition / Information on Ingredients
space
Hazardous component(s) CAS # Percent PEL TLV
ACETONE 67-64-1 > 90 750 ppm 500
space
Non-hazardous component(s) CAS # Percent
2,2',3,3',4,4',6-Heptachlorobiphenyl 35065-29-3 0.01 - 0.1
2,3-Dichlorobiphenyl 25569-80-6 0.01 - 0.1
3-BENZOYLPROPIONIC ACID 2051-95-8 0.01 - 0.1
space
2,2',3,3',4,5',6,6'-Octachlorobiphenyl 68194-17-2 0.01 - 0.1
2,2',3',4,6-Pentachlorobiphenyl 60233-25-2 0.01 - 0.1
2,2',4,4',5,6'-Hexachlorobiphenyl 35065-30-6 0.01 - 0.1
space
2,2',4,4'-Tetrachlorobiphenyl 2437-79-8 0.01 - 0.1
2,4,5-Trichlorobiphenyl 16606-02-3 0.01 - 0.1
space
.
3. Hazards Identification
space
Health: 2*
HMIS RATINGS
Flammability: 3
Physical hazard: 0
space
Health: 2
NFPA RATINGS
Flammability: 3
Instability: 0
.
4. First Aid Measures
space
First Aid
Skin contact
If skin irritation persists, call a physician. Wash off immediately with soap and plenty of water
removing all contaminated clothes and shoes.
Material ID 17377 Material Name PCB Congener mix for Method 525.2
1/ 4
MSDS US
space
Eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
space
Inhalation
Move to fresh air. Oxygen or artificial respiration if needed. Call a physician or Poison Control
Centre immediately.
space
Ingestion
If a person vomits when lying on his back, place him in the recovery position.
space
.
5. Fire Fighting Measures
space
Specific methods
In the event of fire, cool tanks with water spray.
space
.
6. Accidental Release Measures
space
Personal precautions
Use personal protective equipment. Keep people away from and upwind of spill/leak.
space
Environmental precautions
Prevent further leakage or spillage if safe to do so.
space
Methods for cleaning up
Dam up. Soak up with inert absorbent material. Shovel into suitable container for disposal.
space
.
7. Handling and Storage
space
Handling
Keep away from heat and sources of ignition.
space
.
8. Exposure Controls / Personal Protection
space
Exposure Limit Values
ACGIH - Threshold Limits Values - Time Weighted Averages (TLV-TWA)
ACETONE 67-64-1 500 ppm TWA
OSHA - Final PELs - Time Weighted Averages (TWAs)
ACETONE 67-64-1 1000 ppm TWA; 2400 mg/m3 TWA
space
Exposure Controls
Engineering measures to reduce exposure
Provide adequate ventilation.
space
Respiratory protection
In the case of respirable dust and/or fumes, use self-contained breathing apparatus. Wear a
positive-pressure supplied-air respirator.
space
Hand protection
gloves
space
Eye protection
goggles If splashes are likely to occur, wear:
space
.
9. Physical & Chemical Properties
space
Important health, safety and environmental information
-4 ??F (-20 ??C) estimated
Flash Point
space
869 ??F (465 ??C) estimated
Auto Ignition
space
Flammable IB
Flammability Class
Material ID 17377 Material Name PCB Congener mix for Method 525.2
2/ 4
MSDS US
space
133.2 ??F (56.2 ??C) estimated
Boiling Point
space
-138.5 ??F (-94.7 ??C)
Freezing Point
space
-139.7 ??F (-95.4 ??C) estimated
Melting Point
space
100 - 140 ppm
Odor Threshold
space
2 g/l
Vapor Density
space
244.3324 hPa estimated
Vapor Pressure
space
99.6 % estimated
Volatile Organic
space
0.303 Pas 25 C
Viscosity
space
.
10. Chemical Stability & Reactivity Information
space
Further information
Stable at normal conditions
space
.
11. Toxicological Information
space
Acute Toxicity
NIOSH - Selected LD50s and LC50s
ACETONE 67-64-1 Inhalation LC50 Rat: 50100 mg/m3/8H; Inhalation
LC50 Mouse: 44 g/m3/4H; Oral LD50 Rat: 5800
mg/kg; Oral LD50 Mouse: 3 g/kg
space
Carcinogenicity Data
ACETONE
Ingredient(s)
- ACGIH Not Classified Carcinogen
space
Symptoms and Target Organs
NIOSH - Pocket Guide - Target Organs
ACETONE 67-64-1 respiratory system, skin, eyes, CNS
space
.
12. Ecological Information
space
Ecotoxicity
Ecotoxicity - Freshwater Fish Species Data
ACETONE 67-64-1 96 Hr LC50 rainbow trout: 5540 mg/L (Static);96 Hr
LC50 fathead minnow: 6210 mg/L (flow-through);96
Hr LC50 bluegill: 8300 mg/L (Static)
Ecotoxicity - Water Flea Data
ACETONE 67-64-1 48 Hr LC50 water flea: 0.0039 mg/L;48 Hr EC50
water flea: 12700 mg/L (Static)
space
.
13. Disposal Considerations
space
Disposal Instructions
In accordance with local and national regulations.
space
.
14. Transportation Information
space
US DOT
space
Other Information
DOT regulated, small quantity provisions apply (see 49CFR173.4) According to IATA respectively
ICAO exempt from regulations up to 1 per each inner packaging and 3 per each outer packaging.
space
Material ID 17377 Material Name PCB Congener mix for Method 525.2
3/ 4
MSDS US
.
15. Regulatory Information
space
US Federal Regulations
CERCLA/SARA - Hazardous Substances and their Reportable Quantities
ACETONE 67-64-1 5000 lb final RQ; 2270 kg final RQ
DEA (Drug Enforcement Administration) - List II or Essential Chemicals
ACETONE 67-64-1 500 gallon Import/Export Volume; 1,500 kg
Import/Export Weight; 50 gallon Domestic Volume;
150 kg Domestic Weight
space
State Regulations
Massachusetts - Right To Know List
ACETONE 67-64-1 Present
Massachusetts - Toxics Use Reduction Act
ACETONE 67-64-1 CERCLA and 313 chemical
space
International Regulations
Canada - WHMIS - Ingredient Disclosure List
ACETONE 67-64-1 1 % (English Item 10, French Item 41)
.
16. Other Information
space
Disclaimer
The information provided in this Material Safety Data Sheet is based on our present knowledge,
and believed to be correct at the date of publication. However, no representation is made
concerning its accuracy and completeness. It is intended as guidance only, and is not to be
considered a warranty or quality specification. All materials may present unknown hazards, and
should be used with caution. Although certain hazards are described, we cannot guarantee that
these are the only hazards which exist. PerkinElmer Life and Analytical Sciences shall not be held
liable for any damage resulting from handling or from contact with the product.
space
Material ID 17377 Material Name PCB Congener mix for Method 525.2
4/ 4
MSDS US