Construction and application of amperometric Sarcosine (cas 107-97-1) biosensor based on SOxNPs/AuE for determination of prostate cancer
-
Add time:08/26/2019 Source:sciencedirect.com
An improved amperometric Sarcosine (cas 107-97-1) biosensor was constructed based on covalent immobilization of sarcosine oxidase nanoparticles (SOxNPs) onto gold electrode (AuE). The SOxNPs/AuE was characterized by scanning electron microscopy (SEM), fourier transform infrared (FTIR) spectroscopy and electrochemical impedance spectroscopy (EIS) at different stages of its construction. The biosensor worked optimally within 2 s at a potential of 1.0 V, against Ag/AgCl, pH 6.5 and 35 °C. A linear relationship was observed between sarcosine concentration range, 0.1–100 μM and the biosensor response i.e. current in mA under optimum conditions. The biosensor offered a low detection limit of 0.01 μM and gratifying storage stability. The SOxNPs/AuE was unaffected by a number of serum substances at their physiological concentrations. The biosensor measured sarcosine level in sera collected from persons suffering from prostate cancer (mean13.5 μM, n = 8), which was significantly higher (p < 0.01) than those in apparently healthy persons (mean 2.2 μM, n = 8). The SOxNPs/Au electrode was reused 300- times during the span of 180 days, with only 10% loss in its initial activity while being stored dry at 4 °C.
We also recommend Trading Suppliers and Manufacturers of Sarcosine (cas 107-97-1). Pls Click Website Link as below: cas 107-97-1 suppliers
Prev:Platinum-loaded mesoporous nickel phosphonate and its electrochemical application for Sarcosine (cas 107-97-1) detection
Next:ArticleSarcosine (cas 107-97-1) Is Uniquely Modulated by Aging and Dietary Restriction in Rodents and Humans) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- ArticleSarcosine (cas 107-97-1) Is Uniquely Modulated by Aging and Dietary Restriction in Rodents and Humans08/27/2019
- Platinum-loaded mesoporous nickel phosphonate and its electrochemical application for Sarcosine (cas 107-97-1) detection08/25/2019
- A highly sensitive DNA aptamer-based fluorescence assay for Sarcosine (cas 107-97-1) detection down to picomolar levels08/24/2019
- In vitro selection of DNA aptamers for the development of fluorescent aptasensor for Sarcosine (cas 107-97-1) detection08/23/2019
- Fabrication of an amperometric Sarcosine (cas 107-97-1) biosensor based on Sarcosine (cas 107-97-1) oxidase/chitosan/CuNPs/c-MWCNT/Au electrode for detection of prostate cancer08/22/2019
- Xylose as preferred substrate for Sarcosine (cas 107-97-1) production by recombinant Corynebacterium glutamicum08/21/2019
- A novel and sensitive Sarcosine (cas 107-97-1) biosensor based on organic electrochemical transistor08/20/2019
- Amperometric Sarcosine (cas 107-97-1) biosensor based on hollow magnetic Pt–Fe3O4@C nanospheres08/19/2019
- Towards Sarcosine (cas 107-97-1) determination in urine for prostatic carcinoma detection08/18/2019
-
Health and Chemical more >